The DX100 is a single zone lighting
control unit for use with the GX200 12 volt PIR detectors.
The detectors are wired to the DX100 using 4 core alarm
cable and up to six detectors may be connected.
A PC35 relay module may be plugged on to the DX100 for CCTV
interface. (See PC35).
The circuitry is housed within an IP66 enclosure for outdoor
use.
SPECIFICATION:
Mains input voltage: 220-240 volts 50hz
Power switching: 3KW resistive with 12 amp relay
Adjustable timer control from 5 seconds to 15 minutes
Adjustable light sensor control
Output voltage: 12 volts DC
Switched 12 volt output for sounders
Position to plug on a PC35 relay module for CCTV interface
Waterproof IP66 enclosure

|